This cause is confirmed by identifying the hardware generation of the R7 unit in relation to regional cellular infrastructure changes. Because legacy R-series units utilize internal modems designed for 3G network bands, the permanent decommissioning of these networks by cellular providers renders the embedded hardware incapable of establishing a data connection. To diagnose this, perform a hard power cycle by switching off the unit at the main isolator for 60 seconds; if the unit powers on and performs a charging function but fails to regain a server handshake or network-connected LED status after 2 minutes, the issue is confirmed as a permanent network-hardware incompatibility due to the 3G sunset.