Safety Precautions: Ensure the battery is disconnected from the charger before beginning. Handle the lithium-ion battery with care to avoid damage to the casing.
Steps:
- Remove the battery from the charging unit and place it on a stable, non-conductive surface.
- Locate the fuel gauge button on the battery housing.
- Press the fuel gauge button three times in rapid succession.
- On the third press, immediately hold the button down for 7 to 10 seconds.
- Monitor the LED indicator lights on the battery; the reset is successful when the lights flash green, indicating the internal BMS logic has re-initialized.
- Re-insert the battery into the charger to verify that the charging cycle initiates normally.