Calibration issues involve discrepancies between the slicer instructions and the printer's physical output. Confirm this by performing an E-step test: mark 100mm of filament, command the printer to extrude 100mm, and measure the remaining distance. If the actual amount passed is less than 100mm, the firmware E-steps or the slicer's flow rate multiplier are likely set incorrectly.