Industrial Magnet Control System Failure Diagnosis

To confirm a control system failure, inspect the main contactor in the control cabinet while the 'ON' signal is active. Use a multimeter to verify if the control voltage is present at the coil terminals. If voltage is present but the contactor remains open, the internal solenoid mechanism is likely seized or the control circuit is interrupted by an open thermal overload switch.