Tesla CC_a001 Due to Improper Facility Grounding where the Wall Connector is Installed

No ground connection detected in the Wall Connector.

The most likely cause is that the electrical circuit supplying the Wall Connector lacks a valid, high-integrity connection to the building's grounding system. To confirm this, a qualified electrician must use a multimeter to measure voltage potential between L1 and Ground, and L2/N and Ground at the terminal block. A significant deviation or lack of continuity between the ground wire and the true earth reference indicates the facility grounding system is insufficient or non-existent.