DRV8874 Overcurrent Fault Due to Inrush Current

Identify if the fault correlates with high-acceleration motor commands. Use an oscilloscope to compare the control PWM signal duty cycle against the IPROPI current feedback. A direct, instantaneous transition from 0% to 100% duty cycle that results in a current waveform exceeding 6A peak or the configured ITRIP level confirms that the motor's mechanical inertia is creating an excessive inrush current spike that the driver cannot accommodate.