Implement Software PWM Acceleration Ramping

This remedy mitigates inrush current by replacing instantaneous full-duty cycles with a controlled ramp-up period, preventing the DRV8874 from triggering an overcurrent fault.

  1. Tools Required: Development environment (IDE) for your microcontroller, oscilloscope for verification.
  2. Safety Precautions: Ensure the motor is mechanically secured to prevent unexpected movement during testing. Disconnect power before modifying any physical wiring.
  3. Adjust Software Logic: Modify your motor control algorithm to transition the PWM duty cycle from 0% to 100% gradually. Aim for a ramp-up duration of approximately 150ms rather than an instantaneous step.
  4. Test and Monitor: Connect an oscilloscope probe to the IPROPI pin. Run the new motor control script and observe the voltage waveform on the oscilloscope.
  5. Verify Fix: Confirm that the peak voltage measured at the IPROPI pin during the ramp-up phase corresponds to a current value below the 6A threshold and below your configured ITRIP limit. Ensure the nFAULT pin remains high throughout the acceleration process.