Tesla Wall Connector GFCI Fault Due to Incorrect Branch Wiring

This is the most likely cause, confirmed by an electrician using a multimeter at the unit's terminal block. To verify, confirm that the earth ground is not incorrectly connected to a conductor wire. Measure voltage between L1 and Ground, and L2 and Ground; an incorrect reading or continuity between the ground and a conductor indicates a branch circuit installation error.