X1 / X1C - How to Remove Broken Filament from a Bambu Lab Extruder
This procedure is required to remove severely jammed Silk PLA that has been flattened or ground by the extruder gears.
Safety Precautions
Power off and unplug the printer from the wall outlet before starting.
Allow the hotend to cool completely to room temperature.
Tools Needed
H1.5 and H2.0 hex wrenches
Tweezers
Needle-nose pliers
Steps
Remove the toolhead front cover by unfastening the screws.
Disconnect the toolhead fan and sensor cables as required for your printer model.
Unfasten the extruder assembly from the backplate/hotend mount.
Open the internal housing of the extruder gear assembly carefully.
Use tweezers to extract all flattened Silk PLA debris from the gear teeth.
Inspect the drive gears for permanent damage or stripped teeth.
Reassemble the extruder housing and remount the assembly onto the toolhead.
Verification
Once reassembled, power on the printer and perform a manual Load/Unload filament test via the touchscreen to ensure the gears move smoothly and the filament path is clear.